Anaphora
In order to facilitate the Research & Development engineers to find the silicone wire specifications , 《Common electronic wire Specifications 》.
This standard is one of the series standards of design technical standard system , that Product Research & Development center of our company .
References in this standard :
-《Common Wire Number & Section Dimensions》 is provided by Shenzhen XingGuang Electric Heating Products Co., LTD.
-《Common Electronic Wire Code & Related Parameters》is provided by Shenzhen XingGuang Electric Heating Products Co., LTD.
Appendix 《Minimum Cross-sectional Area of Conductors》
This standard is proposed by the standardization project team of Product Research & Development Center.
The main draftsman of this standard : 2015-11-25
Approver of this standard :
1、Subject content and scope of application:
This standard specifies the electronic wire specification number and related parameters.
This standard applies to controlled drawings , engineering BOM and other technical documents.
2、Common line specification number and section size:
| Wire gauge AWG (American wire gauge) | diameter(mm) | area(mm2) | 
| 10 | 2.588 | 5.262 | 
| 11 | 2.305 | 4.172 | 
| 12 | 2.053 | 3.309 | 
| 13 | 1.828 | 2.624 | 
| 14 | 1.628 | 2.081 | 
| 15 | 1.450 | 1.650 | 
| 16 | 1.291 | 1.309 | 
| 17 | 1.150 | 1.037 | 
| 18 | 1.024 | 0.8226 | 
| 19 | 0.912 | 0.6529 | 
| 20 | 0.812 | 0.5174 | 
| 21 | 0.723 | 0.4105 | 
| 22 | 0.644 | 0.3256 | 
| 23 | 0.573 | 0.2581 | 
| 24 | 0.511 | 0.2047 | 
| 25 | 0.455 | 0.1623 | 
| 26 | 0.405 | 0.1288 | 
| 27 | 0.361 | 0.1021 | 
| 28 | 0.321 | 0.08097 | 
| 29 | 0.286 | 0.06422 | 
| 30 | 0.255 | 0.05097 | 
| 31 | 0.227 | 0.04039 | 
3、Commonly used electronic line number and related parameters
| Number | UL number | Temperature resistance(℃) | Rated voltage(V) | Insulation materials | Test voltage(V) | 
| 1 | 1007 | 80 | 300 | PVC | 
 | 
| 2 | 1015 | 105 | 600 | PVC | 
 | 
| 3 | 1332 | 200 | 300 | Teflon | 2500 | 
| 4 | 10362 | 250 | 600 | Teflon | 2500 | 
| 5 | 1815 | 250 | 300 | Teflon | 4000 | 
| 6 | 3122 | 200 | 300 | Silicone rubber (inner), glass fiber woven (outer) | 1500 | 
| 7 | 3239 | 150 | 300/600/10000 | silicon rubber | 6000/25000 | 
| 8 | 3135 | 200 | 600 | silicon rubber | 2000 | 
Note: Temperature data for reference.
Appendix A
(Information Appendix)
A. 1 Minimum cross-sectional area of A conductor:
| Rated current of the appliance(A) | Nominal cross-sectional area(mm2) | 
| ≤0.2 | Foil wire a | 
| >0.2 and ≤3 | 0.5a | 
| >3 and ≤6 | 0.75 | 
| >6 and ≤10 | 1(0.75)b | 
| >10 and ≤16 | 1.5(1.0)b | 
| >16 and ≤25 | 2.5 | 
| >25 and ≤32 | 4 | 
| >32 and ≤40 | 6 | 
| >40 and ≤63 | 10 | 
Footnote a: It can be used only when the exposed length of the power cord does not exceed 2m.